How much insulation do you actually need to buy? This free insulation calculator works it out from the area you are covering, the R-value you are aiming for, and the insulation type.
Enter the net area to cover, in square feet. For a wall, that is length times height minus the window and door openings. ENERGY STAR recommends R-30 to R-60 in attics, with R-49 or more for most of the United States, and R-13 to R-21 in 2x4 and 2x6 walls. The waste allowance covers cutting, fitting around obstacles and offcuts; 5 percent is a typical allowance, and board jobs with many cuts often need 10 percent.
Default prices are 2026 US figures: $4.00 per batt, $15.97 per 25 lb bag of cellulose, $0.60 per board foot of open-cell spray foam installed, $1.50 per board foot of closed-cell spray foam installed, and $60.00 per 2 in XPS sheet. Spray foam is quoted installed because it is almost always applied by a contractor, while the other defaults are material only. Replace the price with your supplier's quote; the estimate does not include labor for batts, cellulose or board, or accessories such as adhesive, tape and fasteners.
Please enter values above 0 for the area and the target R-value, and 0 or more for the waste and price.
| Insulation Type | R per Inch | Thickness (in) | Quantity Needed | Estimated Cost |
|---|
Each row covers the same area and target R-value entered above, with the same waste allowance. Costs use the default price for each type: $4.00 per batt, $15.97 per 25 lb bag, $0.60 per board foot open-cell, $1.50 per board foot closed-cell, $60.00 per 2 in sheet. Change the price input to reprice the selected type in the Summary tab.
Founder & CEO, Techraxy
Faiq Ur Rahman is a web designer, digital product developer, and Founder of Techraxy, a growing platform of online calculators and utility tools. He specializes in building structured, user-friendly tools focused on finance, health, conversions, productivity, and everyday problem-solving. He is passionate about developing practical digital solutions that make complex tasks simpler for users worldwide.
User Ratings:
ADVERTISEMENT
ADVERTISEMENT
How much insulation do you actually need to buy? This free insulation calculator works it out from the area you are covering, the R-value you are aiming for, and the insulation type. It gives the thickness needed, the material volume, and the quantity in the unit each type is sold in: batts for fiberglass, bags for blown cellulose, board feet for spray foam, and 4 by 8 ft sheets for rigid foam board. Add your price per unit and it estimates the cost too. The Compare tab puts all five types side by side for the same area and target R-value, so the trade-off between thickness, quantity and price is easy to see.
An insulation calculator turns a target R-value into a shopping list. R-value measures resistance to heat flow: the higher the number, the better the insulation. Each material delivers a certain R-value per inch of thickness, so the thickness you need is the target R-value divided by the material’s R-value per inch. Closed-cell spray foam at about R-6.5 per inch reaches R-38 in under 6 inches, while a fiberglass batt at about R-3.2 per inch needs nearly 12 inches for the same R-value.
The five types in this calculator cover the common choices, with these R-values per inch:
R-values vary by product, by batch and by temperature, so always check the datasheet for the product you buy. The values above are representative figures inside the published ranges, and the content states the range for each type.
Thickness needed (in) = target R-value / R-value per inch
Area with waste (sq ft) = area (sq ft) x (1 + waste percent / 100)
Material volume (cu ft) = area with waste (sq ft) x thickness (in) / 12
Batts needed = area with waste / 9.6875, rounded up
Bags of cellulose needed = area with waste / 1,000 x bags per 1,000 sq ft at the target R-value, rounded up
Board feet of spray foam = area with waste (sq ft) x thickness (in)
Sheets of rigid board = layers x (area with waste / 32, rounded up); layers = thickness (in) / 2, rounded up
Estimated cost = quantity x price per unit
A standard fiberglass batt piece is 15 in x 93 in, which covers 15 x 93 / 144 = 9.6875 square feet. A standard rigid board sheet is 4 ft x 8 ft, or 32 square feet. A board foot is 1 square foot at 1 inch thick, the unit spray foam contractors price by.
Cellulose bag counts come from the GreenFiber SANCTUARY coverage chart for 25 lb bags, which gives bags per 1,000 square feet at each R-value: R-13 needs 16 bags, R-19 needs 23, R-22 needs 27, R-30 needs 39, R-38 needs 53, R-44 needs 64, R-49 needs 71, and R-60 needs 87. Counts between chart points are linearly interpolated, and counts outside the chart extend the nearest segment. Other brands and bag weights have different charts: a 30 lb bag covers more per bag and a 19 lb bag covers less, so always check the chart on the bag you are buying.
An attic floor of 1,000 sq ft, target R-38, fiberglass batt. All steps below use the unrounded values; displayed figures are rounded to two decimals only at the end.
Thickness needed = 38 / 3.2 = 11.875 in, displayed as 11.88 in.
Area with waste = 1,000 x 1.05 = 1,050.00 sq ft.
Material volume = 1,050 x 11.875 / 12 = 1,039.0625 cu ft, displayed as 1,039.06 cu ft.
Batts needed = 1,050 / 9.6875 = 108.3871, rounded up to 109 batts.
Estimated material cost = 109 x $4.00 = $436.00.
So the attic needs 109 batts at 11.88 inches thick, about $436.00 in material at the default price.
Cellulose example: 500 sq ft, target R-30, blown cellulose.
Thickness needed = 30 / 3.6 = 8.3333 in, displayed as 8.33 in.
Area with waste = 500 x 1.05 = 525.00 sq ft.
Material volume = 525 x 8.3333 / 12 = 364.5833 cu ft, displayed as 364.58 cu ft.
Bags needed = 525 / 1,000 x 39 = 20.475, rounded up to 21 bags.
Estimated material cost = 21 x $15.97 = $335.37.
So the job needs 21 bags of cellulose at 8.33 inches thick, about $335.37 in material at the default price.
It depends on where the insulation goes and your climate zone. ENERGY STAR recommends R-30 to R-60 in attics, with R-49 or more for most of the United States, and R-13 to R-21 for 2×4 and 2×6 walls. Floors over unheated spaces usually take R-25 to R-30. New construction minimums are in the energy code your area adopts, usually the 2021 IECC, which sets wall targets such as R-20 cavity plus R-5 continuous insulation in zones 4 and 5. If your attic already has 3 to 4 inches of insulation, ENERGY STAR’s top-up target is lower than for a bare attic. Check your climate zone and local code before settling on a number.
Because real jobs never use exactly the net area. Batts get cut around wiring, pipes and outlets, and the offcuts rarely fit the next bay. Boards get cut around piers, pipes and corners, and a cut edge is waste. Five percent is a typical allowance for straightforward jobs; board work with many cuts often needs 10 percent. Blown-in cellulose and spray foam have little cutting waste, but installers still overblow slightly to hit the settled depth, so the same allowance is a reasonable cushion. Set it to 0 if you want the bare minimum.
The bag count depends on the target R-value, because one bag covers less area as the depth grows: a 25 lb bag of GreenFiber SANCTUARY covers about 65.8 square feet at R-13 but only 19 square feet at R-38. That is why this calculator reads the manufacturer’s coverage chart instead of using one flat coverage figure. Cellulose also settles about 10 percent after blowing, so the chart counts settled depth: blow to the deeper installed depth on the chart and it sinks to the settled depth that delivers the R-value. Under the FTC’s R-value Rule, every loose-fill package carries this chart, so check the one on the bag you buy, since other brands and bag weights differ.
Yes, and it is common. R-values add up, so layers of different materials stack: batts in the stud bays plus a blown top-up over an attic floor, rigid board over the studs for continuous insulation plus batts in the cavities, or a thin flash coat of closed-cell spray foam for air sealing with batts or cellulose filling the rest of the bay. Two rules matter. Do not compress a batt to fit a thinner cavity, since a compressed batt loses R-value. And air-seal first: insulation slows heat flow but does not stop air leaks, and air moving through or around insulation cuts its real-world performance.
Up to a point, and with diminishing returns. Each added inch saves less than the one before it, because the heat flow it blocks is already smaller. Going from nothing to R-30 saves far more than going from R-30 to R-60. That is why the biggest wins usually come from insulating a bare attic and sealing air leaks, not from chasing the highest R-value everywhere. ENERGY STAR estimates that air sealing and insulating together save an average of about 15 percent of heating and cooling costs. If the budget is limited, spend it on the bare spots and the air leaks first.
This calculator gives planning estimates from the area, R-value and prices you enter. R-values vary by product, by batch and by temperature, and the figures used here are representative values inside the published ranges, so check the datasheet for the product you buy. Cellulose bag counts use one manufacturer’s chart for 25 lb bags; other brands and bag weights differ, and the chart on your bag governs. Prices change by store, region and quantity, and the cost figure is an estimate, not a quote: foam figures are installed rates, while batt, cellulose and board figures are material only and leave out labor, adhesive, tape, fasteners and accessories. Foam board needs a code-compliant fire covering in living spaces, and spray foam should be applied by a trained contractor. Check your local energy code and building code before ordering.