Before the first arc is struck, one number decides whether a steel will weld easily or crack in the heat-affected zone: the carbon equivalent. This free carbon equivalent calculator works it out from the mill certificate chemistry using the IIW formula, and also gives the Pcm cracking parameter for low-carbon steels.
Take the figures from the mill certificate for the heat you are welding, not from the grade name: two heats of the same grade can have different carbon equivalents. Enter each element as a weight percentage and leave an element at 0 if the certificate does not list it. Silicon and boron are only used by the Pcm formula; the IIW carbon equivalent does not use them.
Please enter a carbon content above 0, and no negative values.
| Carbon Content | CE (IIW) | Pcm | Weldability Band |
|---|
Each row uses the alloying elements entered above, with only the carbon content changed. Carbon has the largest single effect on the carbon equivalent, which is why the band moves from good to poor as the carbon content rises.
Founder & CEO, Techraxy
Faiq Ur Rahman is a web designer, digital product developer, and Founder of Techraxy, a growing platform of online calculators and utility tools. He specializes in building structured, user-friendly tools focused on finance, health, conversions, productivity, and everyday problem-solving. He is passionate about developing practical digital solutions that make complex tasks simpler for users worldwide.
User Ratings:
ADVERTISEMENT
ADVERTISEMENT
Before the first arc is struck, one number decides whether a steel will weld easily or crack in the heat-affected zone: the carbon equivalent. This free carbon equivalent calculator works it out from the mill certificate chemistry using the IIW formula, and also gives the Pcm cracking parameter for low-carbon steels. Enter the weight percentages of carbon, manganese, silicon, chromium, molybdenum, vanadium, nickel, copper and boron, and it shows the CE value, the weldability band, the preheat guidance and whether Pcm flags a cold cracking risk.
The carbon equivalent (CE) folds a steel’s whole chemical analysis into a single number that predicts how hard the heat-affected zone (HAZ) becomes as it cools after welding. Carbon hardens the HAZ most, but manganese, chromium, molybdenum, vanadium, nickel and copper all add to the effect, each weighted by how strongly it promotes hard martensite. A high CE means a hard, brittle HAZ that is prone to hydrogen-induced cold cracking, so preheat and low-hydrogen consumables are needed to slow the cooling and keep hydrogen out.
The standard formula is the one published by the International Institute of Welding (IIW), which is also the CEV used in EN 1011-2 and the formula adopted by AWS D1.1. It applies to carbon and carbon-manganese steels and is quoted on mill certificates and in steel standards. The weldability bands are: CE up to 0.40 is good, the steel normally welds without preheat; CE from 0.40 to 0.60 is limited, preheat may be needed, typically 100 to 200 degrees C on thick sections, with low-hydrogen electrodes; CE above 0.60 is poor, preheat is usually required, typically 200 to 350 degrees C, with post-weld heat treatment often part of the procedure.
Pcm is the Ito-Bessyo cracking parameter, developed in Japan in 1968 for modern low-carbon and high-strength low-alloy (HSLA) steels, where the IIW formula tends to overstate the risk because it weights the alloying elements heavily. Pcm weights carbon much more strongly and includes silicon and boron, which the IIW formula leaves out. As a rule of thumb, CE (IIW) governs when carbon is above 0.15 percent and Pcm governs below it. Separately, a Pcm above 0.35 indicates high susceptibility to hydrogen-assisted cold cracking whatever the CE band says.
Once the steel is judged weldable, the Welding Calculator estimates how much electrode or wire the joint needs and the heat input per millimetre for the chosen process.
CE (IIW) = C + Mn / 6 + (Cr + Mo + V) / 5 + (Ni + Cu) / 15
Pcm (Ito-Bessyo) = C + Si / 30 + (Mn + Cu + Cr) / 20 + Ni / 60 + Mo / 15 + V / 10 + 5B
All elements are weight percentages from the mill certificate. In the IIW formula, manganese counts at one sixth of its percentage, chromium, molybdenum and vanadium together at one fifth, and nickel and copper together at one fifteenth. In the Pcm formula, carbon counts in full, silicon at one thirtieth, manganese, copper and chromium together at one twentieth, nickel at one sixtieth, molybdenum at one fifteenth, vanadium at one tenth, and boron at five times its percentage.
Weldability bands (IIW carbon equivalent):
Pcm flag: Pcm above 0.35 indicates high susceptibility to hydrogen-assisted cold cracking, regardless of the CE band.
Governing index: CE (IIW) when carbon is above 0.15 percent; Pcm when carbon is 0.15 percent or below. Other references put the changeover between 0.12 and 0.18 percent carbon; this calculator follows the 0.15 percent convention and always shows both values, so a disagreement between them is visible.
A typical structural steel heat: C 0.18, Mn 1.40, Si 0.30, Cr 0.05, Mo 0.02, V 0.01, Ni 0.05, Cu 0.10, B 0. All steps below use the unrounded values; displayed figures are rounded to three decimals only at the end.
CE (IIW) = 0.18 + 1.40 / 6 + (0.05 + 0.02 + 0.01) / 5 + (0.05 + 0.10) / 15
= 0.18 + 0.2333333 + 0.016 + 0.01
= 0.4393333, displayed as 0.439.
Pcm = 0.18 + 0.30 / 30 + (1.40 + 0.10 + 0.05) / 20 + 0.05 / 60 + 0.02 / 15 + 0.01 / 10 + 5 x 0
= 0.18 + 0.01 + 0.0775 + 0.0008333 + 0.0013333 + 0.001 + 0
= 0.2706667, displayed as 0.271.
CE 0.439 sits in the limited band (0.40 to 0.60), so preheat may be needed on thick sections with low-hydrogen electrodes. Pcm 0.271 is below the 0.35 flag, so Pcm raises no additional cold cracking warning. Carbon is 0.18 percent, above 0.15, so CE (IIW) is the governing index. This is the same composition used in a published worked example, which also gives CE 0.439.
As a rule of thumb, a CE (IIW) below 0.40 is generally weldable without preheat on thin sections under low restraint, provided low-hydrogen consumables are used. Between 0.40 and 0.60 preheat may be needed, typically 100 to 200 degrees C on thick metal, and above 0.60 preheat is usually required. Thickness, joint restraint and the hydrogen level of the process all shift the real requirement, so the band is a screening result and the exact preheat comes from EN 1011-2 or AWS D1.1 for the actual joint. Some references use finer bands, for example excellent up to 0.35, very good to 0.40, good to 0.45, fair to 0.50 and poor above 0.50.
Use CE (IIW) for ordinary carbon and carbon-manganese steels with carbon above about 0.15 percent, and Pcm for modern low-carbon and HSLA steels below that, such as pipeline and fine-grained structural steels. The two formulas were derived on different steels: the IIW formula weights the alloying elements heavily and overstates the risk on low-carbon steels, while Pcm weights carbon far more strongly and accounts for silicon and boron. This calculator shows both and names the governing index, so you can see when they disagree.
Because a grade only sets maximum or range limits for each element, and the actual heat chemistry varies inside those limits. Two heats of S355 can differ by several hundredths of a percent in carbon and manganese, which is enough to move the CE across a band boundary. Always calculate from the mill certificate for the heat being welded. Using the grade’s maximum composition gives a worst-case CE, which is a safe planning figure but can overstate the preheat needed for the actual heat.
No, it only tells you whether preheat is a question at all. The temperature itself depends on the CE (or the CET used in EN 1011-2 method B), the plate thickness, the diffusible hydrogen content of the consumable and the heat input. A steel with CE 0.44 needs no preheat on thin plate but around 70 degrees C at 12 mm with typical hydrogen levels, and more as the thickness grows. Size the preheat with EN 1011-2 Annex C or AWS D1.1 Annex H, or take it from the qualified welding procedure specification.
Take the Pcm flag seriously. Pcm above 0.35 indicates high susceptibility to hydrogen-assisted cold cracking regardless of what CE says, and it most often appears on low-carbon steels where CE understates the risk because the alloying additions are small. Use low-hydrogen consumables, control the heat input, consider preheat even if the CE band does not demand it, and check the requirement against the welding procedure specification for the job.
This calculator gives screening indices for planning only. The carbon equivalent and Pcm describe how readily the heat-affected zone hardens; they do not account for plate thickness, joint restraint, diffusible hydrogen, heat input or the welding procedure, all of which affect whether a weld cracks. The preheat guidance is indicative. Do not use these results to set a preheat temperature or to qualify a weld: follow the applicable code (EN 1011-2, AWS D1.1 or ASME), the steel manufacturer’s recommendations and a qualified welding procedure specification, and confirm the chemistry against the mill certificate for the heat being welded.
ADVERTISEMENT
ADVERTISEMENT