Liters per minute, or L/min, is the flow rate unit on almost every pump label, tap specification and irrigation chart outside the United States, and it is the number you need when you are sizing a pump, checking a tap or working out how long a tank takes to fill. This free liters per minute calculator measures flow two ways, both fully metric. Time how long it takes to fill a container in liters, or enter a pipe diameter in millimeters and a water velocity in meters per second, and it shows the flow in L/min plus GPM, liters per second, cubic meters per hour and gallons per hour, with the time to fill a 200 liter drum and a 1,000 liter tank.
Use the bucket test when you can catch the water and time it. Use the pipe method when you know the pipe size and the water velocity instead.
Fill a container of known size, such as a 20 liter bucket, and time it with a stopwatch. Repeat the test two or three times and use the average time for a steadier result.
Enter the true inside diameter in millimeters, not the outside size printed on the pipe: metric pipe is sized by outside diameter, and the bore is smaller once the wall is subtracted. For example, a 25 mm outside PVC pipe is about 21.2 mm inside at PN16, and a 50 mm outside pipe is about 42.6 mm inside. Household plumbing is usually designed for water velocities of 1 to 2 m/s.
Please enter values above 0 for the inputs of the selected method.
| Flow Rate (L/min) | Flow Rate (GPM) | Liters per Second | Cubic Meters per Hour |
|---|
Reference conversions for common flow rates. GPM uses US gallons: 1 US gallon = 3.78541 liters, so divide L/min by 3.78541 to get GPM. An imperial gallon is larger (4.54609 liters), so UK figures convert differently.
Founder & CEO, Techraxy
Faiq Ur Rahman is a web designer, digital product developer, and Founder of Techraxy, a growing platform of online calculators and utility tools. He specializes in building structured, user-friendly tools focused on finance, health, conversions, productivity, and everyday problem-solving. He is passionate about developing practical digital solutions that make complex tasks simpler for users worldwide.
User Ratings:
ADVERTISEMENT
ADVERTISEMENT
Liters per minute is a volumetric flow rate: the number of liters of water passing a point every minute. It is the standard metric unit for water flow in plumbing, irrigation, pumps, pools and water treatment. A flow of 40 L/min means 40 liters pass the point each minute, which is 2,400 liters, or 2.4 cubic meters, in an hour.
There are two practical ways to find it. The bucket test measures flow directly: catch the water in a container of known size and time it, then L/min = liters / seconds x 60. The pipe method calculates it from the pipe: flow equals the cross-sectional area of the pipe times the speed of the water inside it. In metric units that is L/min = 0.047124 x inside diameter (mm) squared x velocity (m/s), where 0.047124 folds together the circle area formula and the conversion from cubic meters per second to liters per minute (x 60,000).
Metric pipe is sized by outside diameter, so the bore is always smaller than the number on the pipe once the wall is subtracted. A 25 mm outside PVC pipe is about 21.2 mm inside at PN16, and a 50 mm outside pipe is about 42.6 mm inside, so always enter the true inside diameter. All gallon conversions here use US gallons (1 US gallon = 3.78541 liters); an imperial gallon is larger at 4.54609 liters.
Bucket test: L/min = volume (liters) / time (seconds) x 60
Pipe method: L/min = 0.047124 x inside diameter (mm) squared x velocity (m/s)
GPM = L/min / 3.78541
Liters per second = L/min / 60
Cubic meters per hour = L/min x 0.06
Gallons per hour = GPM x 60
Fill time (minutes) = volume (liters) / L/min
The pipe formula is flow = area x velocity in metric units. The cross-sectional area of a round pipe is pi x diameter squared / 4; with the diameter in millimeters that area in square meters is pi x (d / 1000) squared / 4, multiplying by velocity in m/s gives cubic meters per second, and multiplying by 60,000 converts cubic meters per second to liters per minute. Those steps collapse into the single constant 0.047124 (pi / 4 x 60,000 / 1,000,000). The widget computes the area directly from pi rather than from the rounded constant, so the two agree to display precision. The conversion factors are exact unit definitions: 1 US gallon = 3.78541 liters, 1 cubic meter = 1,000 liters, 1 cubic foot = 28.3168 liters.
A bucket test collects 20 liters in 30 seconds. All steps below use the unrounded values; displayed figures are rounded to two decimals only at the end.
L/min = 20 / 30 x 60 = 40.00 L/min.
GPM = 40 / 3.78541 = 10.566887, displayed as 10.57 GPM.
Liters per second = 40 / 60 = 0.666667, displayed as 0.67 L/s.
Cubic meters per hour = 40 x 0.06 = 2.40 m3/h.
Gallons per hour = 10.566887 x 60 = 634.013224, displayed as 634.01 GPH.
Time to fill a 200 liter drum = 200 / 40 = 5.00 min.
Time to fill a 1,000 liter tank = 1,000 / 40 = 25.00 min.
So the tap flows at 40.00 L/min, or 10.57 GPM. Using the pipe method instead, a 25 mm inside diameter pipe with water moving at 1.5 m/s gives an area of pi x (0.025 / 2) squared = 0.000490874 square meters, times 1.5 m/s = 0.000736311 cubic meters per second, times 60,000 = 44.178647, displayed as 44.18 L/min, which is 11.67 GPM.
Time how long it takes to fill a container of known size, then divide the liters by the seconds and multiply by 60. A 20 liter bucket that fills in 30 seconds is 20 / 30 x 60 = 40 L/min. Repeat the test two or three times and average the results, since a single timing can easily be off by a second or two. If you cannot catch the water, use the pipe method instead: L/min = 0.047124 x inside diameter in millimeters squared x velocity in meters per second.
Divide by 3.78541, because 1 US gallon = 3.78541 liters. So 40 L/min is 10.57 GPM, and 100 L/min is 26.42 GPM. To go the other way, multiply GPM by 3.78541. Watch out for the gallon type: these figures use US gallons. An imperial gallon is 4.54609 liters, so a UK gallon per minute is 4.54609 L/min, about 20 percent more than a US GPM.
A bathroom tap typically flows about 6 to 8 L/min, a standard showerhead about 9.46 L/min (2.5 GPM, the US federal maximum; WaterSense models about 7.57 L/min), a garden hose roughly 19 to 38 L/min (5 to 10 GPM), and a residential well pump roughly 19 to 57 L/min (5 to 15 GPM). A household at peak demand, with several fixtures running at once, typically needs about 23 to 45 L/min (6 to 12 GPM). These are planning figures; the real flow depends on pressure and the fixture.
It depends on the velocity you accept: household plumbing is usually designed for 1 to 2 m/s. A 25 mm inside diameter pipe at 1.5 m/s carries 44.18 L/min, while a 50 mm pipe at 2 m/s carries 235.62 L/min. Flow grows with the square of the diameter, so doubling the bore quadruples the flow at the same velocity. Use the pipe method in this calculator to check a size, and remember to enter the true inside diameter, not the outside size printed on the pipe.
Divide the tank volume in liters by the flow rate in L/min. At 40 L/min, a 200 liter drum fills in 5 minutes and a 1,000 liter tank in 25 minutes. At 80 L/min those times halve to 2.5 and 12.5 minutes. The calculator works out both fill times automatically for the 200 liter drum and the 1,000 liter tank; for any other size, divide its volume by your L/min figure.
This calculator gives estimates based on the figures you enter and standard formulas for water flow. Real flow depends on water pressure, pipe condition, fittings, elevation and the accuracy of your timing or velocity estimate, so the results are approximate. The pipe method assumes a steady average velocity across the full bore and clean water at normal temperatures. For pump sizing, irrigation design or any work governed by a plumbing code, confirm the figures with a licensed plumber or engineer. This tool is for planning and estimating only.