How much load can a beam carry before its material is overstressed? This free beam load calculator works it out from the two things that decide the answer: the section’s resistance to bending and the material’s allowable bending stress.
Span is the clear distance between the two supports. For a rectangular section the section modulus is S = b x h squared / 6, so depth matters far more than width: doubling the depth multiplies S by four. For an I-beam, channel or other rolled shape, choose "Enter section modulus S directly" and take S from the steel section tables.
The wood values are NDS design values of Fb for beams and stringers. The steel values are the AISC allowable bending stress Fb = 0.66 x Fy for compact, laterally supported sections: 0.66 x 36 ksi = 24 ksi for A36 and 0.66 x 50 ksi = 33 ksi for A992. No safety factor is applied on top of the allowable stress you enter: if your allowable stress is a yield or ultimate value rather than a code allowable value, divide it by your own safety factor first.
Please enter values above 0 for the span, the section and the allowable stress.
| Span | Allowable Load (selected case) | Reaction (each end) |
|---|
Each row uses the section and allowable stress entered above, at a different span. The allowable point load falls in direct proportion to the span, while the allowable UDL falls with the square of the span, so doubling the span halves the point load but quarters the UDL.
Founder & CEO, Techraxy
Faiq Ur Rahman is a web designer, digital product developer, and Founder of Techraxy, a growing platform of online calculators and utility tools. He specializes in building structured, user-friendly tools focused on finance, health, conversions, productivity, and everyday problem-solving. He is passionate about developing practical digital solutions that make complex tasks simpler for users worldwide.
User Ratings:
ADVERTISEMENT
ADVERTISEMENT
How much load can a beam carry before its material is overstressed? This free beam load calculator works it out from the two things that decide the answer: the section’s resistance to bending and the material’s allowable bending stress. Enter the span, give the section as a rectangle or as a section modulus straight from the steel tables, pick an allowable stress or type your own, and choose a center point load or a uniformly distributed load. It shows the allowable load for both load cases, the allowable bending moment, the section modulus used and the support reactions, and the Compare Spans tab shows how the allowable load falls as the span grows.
A beam load calculator turns an allowable stress into an allowable load. The link between them is the flexure formula. The bending stress at the outer fiber of a beam is the bending moment divided by the section modulus, so the largest moment a section can carry is the allowable stress times the section modulus: M = sigma_allow x S. Once the moment capacity is known, the load that produces that moment follows from the load case. For a center point load on a simply supported beam the maximum moment is P x L / 4, so the allowable point load is P = 4M / L. For a uniformly distributed load the maximum moment is w x L squared / 8, so the allowable UDL is w = 8M / L squared.
The section modulus S is the geometric property that carries the section’s shape: for a rectangle S = b x h squared / 6, so depth matters far more than width, and doubling the depth multiplies S by four. For an I-beam or channel, S comes from the steel section tables, which is why the calculator lets you enter it directly.
The allowable stress is where the engineering judgment lives. For timber it is the NDS design value Fb for the species and grade, already reduced for natural variation in the wood. For steel the classic allowable stress design value is Fb = 0.66 x Fy for compact, laterally supported sections: 24 ksi for A36 and 33 ksi for A992. This calculator applies no safety factor on top of the allowable stress you enter, so if the number you have is a yield or ultimate strength rather than a code allowable value, divide it by your own safety factor before entering it.
Section modulus, rectangle (in^3) = b x h squared / 6
Allowable bending moment (lb-in) = allowable stress (psi) x section modulus (in^3)
Allowable center point load (lb) = 4 x allowable moment (lb-in) / span (in)
Allowable UDL (lb/in) = 8 x allowable moment (lb-in) / span squared (in^2)
Allowable UDL (lb/ft) = allowable UDL (lb/in) x 12
Support reaction each end, point load (lb) = allowable point load / 2
Support reaction each end, UDL (lb) = allowable UDL (lb/in) x span (in) / 2
In these formulas the span enters in inches (feet times 12) and the stress enters in psi. The moment capacity is the same for both load cases, because it depends only on the section and the material; only the conversion from moment to load changes. That is why the allowable point load falls in direct proportion to the span while the allowable UDL falls with the square of the span: doubling the span halves the point load but quarters the UDL.
A Douglas Fir-Larch Select Structural beam, 12 ft span, 6 in wide and 12 in deep, allowable bending stress 1,600 psi, center point load. All steps below use the unrounded values; displayed figures are rounded only at the end.
Section modulus = 6 x 12 squared / 6 = 6 x 144 / 6 = 144 in^3.
Allowable bending moment = 1,600 x 144 = 230,400 lb-in, displayed as 230,400.00 lb-in.
Allowable bending moment in lb-ft = 230,400 / 12 = 19,200 lb-ft.
Allowable center point load = 4 x 230,400 / 144 = 921,600 / 144 = 6,400 lb.
Allowable UDL = 8 x 230,400 / 144 squared = 1,843,200 / 20,736 = 88.8889 lb/in, displayed as 1,066.67 lb/ft.
Support reaction each end at the allowable point load = 6,400 / 2 = 3,200 lb.
So the beam can carry a 6,400 lb point load at midspan, or a uniformly distributed load of 1,066.67 lb/ft, before the outer fiber reaches 1,600 psi.
It is the highest bending stress the material is permitted to reach in service, and it comes from the design code for the material. For timber, the NDS publishes design values of Fb by species and grade: Douglas Fir-Larch Select Structural is 1,600 psi for beams and stringers and No.2 is 875 psi, before adjustment factors for load duration, moisture and size. For steel, the classic allowable stress design value for compact, laterally supported sections is Fb = 0.66 x Fy, which gives 24 ksi for A36 (Fy = 36 ksi) and 33 ksi for A992 (Fy = 50 ksi). The calculator’s presets carry those four values; anything else should come from the code or the material supplier, not from a guess.
No safety factor is applied on top of the allowable stress you enter. That is correct when the stress you enter is already a code allowable value, because the code value already has the safety margin built in: the NDS Fb values are reduced from tested strengths, and the 0.66 x Fy steel value is about two thirds of yield. But if the number you have is a yield strength or an ultimate strength, you must divide it by your own safety factor first. Entering a yield strength as if it were an allowable stress would overstate the safe load by roughly half.
Because the moment each load case produces grows differently with span. A point load’s moment grows in proportion to the span (M = P x L / 4), so holding the moment fixed means P falls as 1 / L: double the span, halve the load. A UDL’s moment grows with the square of the span (M = w x L squared / 8), because both the total load and the lever arm grow with the span, so holding the moment fixed means w falls as 1 / L squared: double the span, quarter the load. The Compare Spans tab shows both patterns side by side.
Yes. Choose “Enter section modulus S directly” and take S from the AISC steel section tables for the shape you are using, making sure to use the strong-axis value S_x for a beam loaded vertically. The allowable stress presets include A36 at 24,000 psi and A992 at 33,000 psi, which are the 0.66 x Fy values for compact, laterally supported sections. If the compression flange is laterally unsupported over a long length, the allowable stress is lower than 0.66 x Fy and this calculator will overstate the capacity, so check lateral-torsional buckling separately.
Bending is only one of several checks. A beam sized by this calculator still needs a shear check, a deflection check against L/360 and L/240, a lateral-torsional buckling check if the compression flange is unbraced, a bearing check where the beam sits on its supports, and a connection check at the hangers or posts. The beam’s own weight is also not included here: it acts as a UDL and comes off the allowable load. A real design needs all of those checks, done by a licensed engineer.
This calculator gives estimates for a simply supported beam in bending only, based on the values you enter. The result is the load at which the extreme fiber reaches exactly the allowable stress you entered, with no safety factor added, and with no check for shear, deflection, lateral-torsional buckling, bearing at the supports, connections or the beam’s own weight. Allowable stress values vary by species, grade, section type, lateral support and code, and the presets are typical values that may not match your specific member. The results are for planning and estimating only and are not a substitute for a design by a licensed engineer.