Cycling Power Zones Calculator

A triathlon bike leg is won on steady power, not on surges. The rider who holds the right watts for five hours runs a strong marathon afterwards; the rider who chases every hill and every passing wheel walks the second half of the run. Power zones make that discipline concrete: seven bands of effort, each built from one number, your functional threshold power, or FTP. This free cycling power zones calculator turns your FTP into all seven Coggan power zones in watts, and into watts per kilogram if you add your body weight, so you can plan a long ride, pace a race and check any effort against its zone in seconds.

The defaults are an FTP of 250 W at 75 kg, with a current power of 200 W to check. At those figures Zone 4, the threshold zone, runs from 225 to 263 W, and 200 W sits at 80.0% of FTP in Zone 3 Tempo. The compare tab builds the same seven zones for FTP values from 150 to 350 W, so you can see how the zones move as fitness changes. This is the triathlete’s zone tool: the article below explains the zones in long-course terms, with Ironman and 70.3 pacing targets, brick sessions and the steady Zone 2 riding that fills most of a triathlon training week.

Your FTP and Body Weight

W
kg
W

FTP is the highest power you can hold for about an hour when fresh. The usual field test is a 20 minute all-out effort: FTP is 95% of your 20 minute average power. Body weight is optional: leave it blank and the calculator shows watts only, with no watts per kilogram. Current power is the effort you want to check: the rider and the marker slide to it on the diagram, and the results name the zone it falls in.

FTP 250 W, 3.33 W/kg at 75 kg Riding at 200 W, 80.0% of FTP, Zone 3 Tempo Marker shows where your current power sits on the zone scale 0 55% 75% 90% 105% 120% 150% 180% Zone 1 Active Recovery: less than 138 W (less than 1.84 W/kg) Zone 2 Endurance: 138 to 188 W (1.84 to 2.51 W/kg) Zone 3 Tempo: 188 to 225 W (2.51 to 3.00 W/kg) Zone 4 Threshold: 225 to 263 W (3.00 to 3.51 W/kg) Zone 5 VO2max: 263 to 300 W (3.51 to 4.00 W/kg) Zone 6 Anaerobic Capacity: 300 to 375 W (4.00 to 5.00 W/kg) Zone 7 Neuromuscular Power: more than 375 W (more than 5.00 W/kg)
Your FTP and current effort
Functional Threshold Power (FTP)
FTP Power to Weight
Current Power
Current Power as % of FTP
Current Zone
Your seven power zones
Zone 1 Active Recovery (less than 55% of FTP)
Zone 2 Endurance (56 to 75% of FTP)
Zone 3 Tempo (76 to 90% of FTP)
Zone 4 Threshold (91 to 105% of FTP)
Zone 5 VO2max (106 to 120% of FTP)
Zone 6 Anaerobic Capacity (121 to 150% of FTP)
Zone 7 Neuromuscular Power (more than 150% of FTP)
Note: FTP is the highest power you can hold for about an hour when fresh. The usual field test is a 20 minute all-out effort, and FTP is 95% of your 20 minute average power. Re-test every 6 to 8 weeks, because zones built on a stale FTP are wrong in every zone at once.
FTP (W)Zone 1Zone 2Zone 3Zone 4Zone 5Zone 6Zone 7

Each row builds the same seven Coggan zones from a different FTP. The 250 W row matches the calculator defaults and is highlighted. Zone 1 is less than 55% of FTP and Zone 7 is more than 150% of FTP, so those two cells show one edge only.

Powered by Techraxy

Creator & Reviewer

Faiq Ur Rahman

Founder & CEO, Techraxy

Faiq Ur Rahman is a web designer, digital product developer, and Founder of Techraxy, a growing platform of online calculators and utility tools. He specializes in building structured, user-friendly tools focused on finance, health, conversions, productivity, and everyday problem-solving. He is passionate about developing practical digital solutions that make complex tasks simpler for users worldwide.

Share:

Rate this Tool

User Ratings:

0
0 out of 5 stars (based on 0 reviews)
Excellent
Very good
Average
Poor
Terrible

ADVERTISEMENT

ADVERTISEMENT

What is a Cycling Power Zones Calculator?

A cycling power zones calculator works out the seven training zones for a cyclist from functional threshold power. FTP is the highest power a rider can hold in a quasi-steady state for about an hour when fresh, and each zone is a percentage band of that figure. The seven zones come from the model developed by Dr Andrew Coggan and Hunter Allen in Training and Racing with a Power Meter, and published by Coggan as the Power Training Levels on TrainingPeaks: Zone 1 Active Recovery below 55% of FTP, Zone 2 Endurance 56 to 75%, Zone 3 Tempo 76 to 90%, Zone 4 Threshold 91 to 105%, Zone 5 VO2max 106 to 120%, Zone 6 Anaerobic Capacity 121 to 150%, and Zone 7 Neuromuscular Power above 150%. Each zone trains something different: Zone 1 recovers, Zone 2 builds the aerobic base, Zone 3 builds tempo endurance, Zone 4 raises the threshold itself, Zone 5 builds maximum oxygen uptake, Zone 6 builds anaerobic capacity, and Zone 7 builds sprint power.

This calculator is different from the other power tools on this site. The Cycling Wattage Calculator works out the watts a ride should cost from speed, weight and gradient, using the physics of air resistance, rolling resistance and gravity. It answers what a ride demands. This calculator answers what those watts mean for training: given the FTP you can actually hold, which band is any effort in, and what is it training. The Cycling Heart Rate Zone Calculator builds five zones from age and resting heart rate instead; power zones are the sharper tool for a triathlete with a power meter, because power responds instantly while heart rate lags behind effort by a minute or more, drifts upward in the heat, and is flattened by fatigue late in a long ride. For the calories a ride at a given zone burns, see the Calories Burned Biking Calculator.

For a triathlete the zones map directly onto the race. A full Ironman bike leg is usually ridden at about 65 to 75% of FTP, the top of Zone 2 into the bottom of Zone 3, and a 70.3 bike leg at about 75 to 85% of FTP, in Zone 3. Those are published coaching ranges, not guarantees, and the honest caveat is that an FTP tested fresh falls by roughly 5 to 15% by the third hour of a long bike leg, so a target set from a fresh FTP gets harder to hold as the race goes on. The zones still give the plan its numbers: a brick session is a long Zone 2 ride followed by a run off the bike, a threshold session is repeats in Zone 4, and the easy days that fill most of the week stay in Zone 2 so the hard days can stay hard.

How to Use the Cycling Power Zones Calculator

  1. Enter your FTP in watts. If you have never tested it, the usual field test is a 20 minute all-out effort: FTP is 95% of your 20 minute average power. See the FAQ below for how to run the test.
  2. Enter your body weight in kilograms if you want watts per kilogram. It is optional: leave it blank and the calculator shows watts only.
  3. Enter a current power in watts to check, for example the average power of your last ride or the target power for your next race. The rider and the marker on the diagram slide to it, and the results name the zone it falls in.
  4. Click Calculate, or just type: the results update as you enter the numbers. The diagram is a cyclist on a road above a seven segment zone scale, and the picture moves with your inputs: the rider slides along the road as current power rises, the speed lines behind the bike strengthen, the marker slides across the zone scale, and the segment and the text line for the zone you are riding in light up while the others fade.
  5. Read the Summary tab for your FTP in watts and watts per kilogram, your current power as a percentage of FTP and its zone, and all seven zones in watts and watts per kilogram.
  6. Open the Compare Zones by FTP tab to see all seven zones for FTP values of 150, 200, 250, 300 and 350 W, with the 250 W row highlighted because it matches the defaults.

Cycling Power Zones Calculator Formula

Zone watts = FTP x zone boundary

Zone 1 = less than 0.55 x FTP

Zone 2 = 0.55 to 0.75 x FTP

Zone 3 = 0.75 to 0.90 x FTP

Zone 4 = 0.90 to 1.05 x FTP

Zone 5 = 1.05 to 1.20 x FTP

Zone 6 = 1.20 to 1.50 x FTP

Zone 7 = more than 1.50 x FTP

Power to weight = watts / body weight in kg

FTP from a 20 minute test = 0.95 x 20 minute average power

Current power as % of FTP = current power / FTP x 100

The zone edges are the six multipliers 0.55, 0.75, 0.90, 1.05, 1.20 and 1.50, applied to FTP. The whole-percent labels in the zone names, 56 to 75% and so on, are rounded versions of those edges, so a power is classified by comparing it with the multipliers, not with the rounded labels: a power at exactly 55% of FTP is the top of Zone 1 by the multiplier, and a power just above it is Zone 2. Watt bounds are rounded to whole watts for display, and watts per kilogram bounds are the displayed watt bounds divided by body weight, to two decimals. FTP itself is a test result, not a formula: it is the highest power a rider can hold in a quasi-steady state for about an hour, and the 20 minute test with the 0.95 factor is the standard field estimate of it, from Allen and Coggan.

One rendering difference is worth stating plainly. Coggan’s original table on TrainingPeaks leaves Level 6 open ended above 121% and gives Level 7 no percentage at all, because a sprint has no meaningful percentage of threshold. This calculator uses the widely published capped rendering, Zone 6 capped at 150% and Zone 7 above 150%, so that every zone has a defined watt range and the calculator can classify any power. The zones below 120% of FTP are identical under both renderings, and the FAQ below explains the difference.

Worked Example

A rider has an FTP of 250 W, weighs 75 kg and wants to check a current power of 200 W. All steps below use the unrounded values; displayed figures are rounded as shown.

Zone 1 = less than 0.55 x 250 = less than 137.5 W, shown as less than 138 W, less than 1.84 W/kg.

Zone 2 = 137.5 to 187.5 W, shown as 138 to 188 W, 1.84 to 2.51 W/kg.

Zone 3 = 187.5 to 225 W, shown as 188 to 225 W, 2.51 to 3.00 W/kg.

Zone 4 = 225 to 262.5 W, shown as 225 to 263 W, 3.00 to 3.51 W/kg.

Zone 5 = 262.5 to 300 W, shown as 263 to 300 W, 3.51 to 4.00 W/kg.

Zone 6 = 300 to 375 W, shown as 300 to 375 W, 4.00 to 5.00 W/kg.

Zone 7 = more than 375 W, more than 5.00 W/kg.

FTP power to weight = 250 / 75 = 3.33 W/kg.

Current power = 200 / 250 x 100 = 80.0% of FTP, which falls between 0.75 and 0.90, so it is Zone 3 Tempo.

At the test case, an FTP of 300 W at 75 kg: Zone 1 is less than 165 W (less than 2.20 W/kg), Zone 2 is 165 to 225 W (2.20 to 3.00 W/kg), Zone 3 is 225 to 270 W (3.00 to 3.60 W/kg), Zone 4 is 270 to 315 W (3.60 to 4.20 W/kg), Zone 5 is 315 to 360 W (4.20 to 4.80 W/kg), Zone 6 is 360 to 450 W (4.80 to 6.00 W/kg), and Zone 7 is more than 450 W (more than 6.00 W/kg). FTP power to weight is 300 / 75 = 4.00 W/kg. The same current power of 200 W is now 66.7% of FTP, in Zone 2 Endurance, because the same watts are a smaller share of a bigger FTP.

The same arithmetic gives race targets. At the default FTP of 250 W, a full Ironman target of 65 to 75% of FTP is 163 to 188 W, the top of Zone 2, and a 70.3 target of 75 to 85% of FTP is 188 to 213 W, in Zone 3. That is why the Ironman bike feels like a long Zone 2 ride and the 70.3 bike feels like a long tempo effort, and why holding Zone 4 power in an Ironman usually ends the run before it starts.

Benefits of Using a Cycling Power Zones Calculator

  • Turns one number, your FTP, into all seven Coggan zones at once, in watts and in watts per kilogram, so a training plan written in zones becomes numbers on your head unit.
  • Classifies any effort instantly: enter the average power of a ride or a race target and the calculator names its zone, so you can see whether your easy rides were easy enough and your hard rides were hard enough.
  • Keeps long-course pacing honest: Ironman power sits in the top of Zone 2 and 70.3 power in Zone 3, and the zones show those targets in watts instead of in feel.
  • Shows watts per kilogram alongside watts, the number that decides climbing speed and lets riders of different weights compare FTP fairly.
  • Uses the Coggan and Allen model as published on TrainingPeaks, with the capped Zone 6 and Zone 7 rendering stated openly, so the zones match the model most coaches and training platforms use.
  • Refuses impossible inputs instead of calculating nonsense: an FTP outside 50 to 600 W, a body weight outside 30 to 200 kg, or a current power outside 0 to 1,500 W all produce a clear error message.
  • Free and instant: no sign-up, no download, and the results and diagram update as you type.

Frequently Asked Questions

How do I find my FTP if I have never tested it?

Ride a 20 minute all-out effort after a thorough warm-up, on a flat road or a trainer, and take 95% of your average power for those 20 minutes. At a 20 minute average of 263 W, FTP is 0.95 x 263 = 250 W, the calculator default. Warm up for at least 20 minutes with a few short hard efforts, ride the test as evenly as you can instead of starting too hard, and use a power meter or a smart trainer: a heart rate monitor cannot measure FTP. A lab test with blood lactate sampling is more precise, but the 20 minute test is the standard field estimate from Allen and Coggan, and it is the one most coaches use. Re-test every 6 to 8 weeks, because zones built on a stale FTP are wrong in every zone at once.

Why does Zone 6 stop at 150% when Coggan’s own table leaves it open?

Because this calculator uses the widely published capped rendering of the same model. Coggan’s original table on TrainingPeaks prints Level 6 as above 121% with no upper edge and gives Level 7 no percentage at all, on the grounds that a sprint is a maximal effort with no meaningful percentage of threshold. Most training platforms and coaching articles cap Zone 6 at 150% and put Zone 7 above 150%, so that every power has a zone. The two renderings agree exactly below 120% of FTP, which covers Zones 1 to 5 and all steady riding, racing and threshold work. Only a power above 120% is affected, and there the capped version calls 121 to 150% Zone 6 and anything above 150% Zone 7, while the original table calls everything above 121% Zone 6 and reserves Zone 7 for maximal sprints judged against past sprints rather than against FTP.

What power should I hold for an Ironman or a 70.3 bike leg?

As a starting point, about 65 to 75% of FTP for a full Ironman and about 75 to 85% of FTP for a 70.3, which at the default FTP of 250 W is 163 to 188 W for the Ironman and 188 to 213 W for the 70.3. First-timers should sit at the low end of each range, and experienced athletes with a strong run off the bike can sit higher. Two caveats matter more than the exact number. First, an FTP tested fresh falls by roughly 5 to 15% by the third hour of a long bike leg, so a target set from a fresh FTP gets harder to hold as the race goes on: start at the low end and let the second half of the bike tell you whether the target was right. Second, test the target in training with a long ride at race power followed by a 5 to 10 km run off the bike: if that run feels like survival, the bike target was too ambitious.

Should I train by power zones or heart rate zones?

Power zones, if you own a power meter, because power is instant and heart rate is not. Power changes the moment you press harder or ease off, while heart rate takes a minute or more to catch up, drifts upward in the heat at the same power, and is flattened by fatigue late in a long ride, so a heart rate zone can read Zone 2 while the legs are working in Zone 4. Heart rate is still useful as a check: if power says Zone 2 but heart rate is drifting into Zone 4 on a hot day, the body is working harder than the watts suggest, and easing off is the right call. The Cycling Heart Rate Zone Calculator builds the five heart rate zones from age and resting heart rate, and the two calculators agree on the shape of training: most time easy, a little time hard, and almost no time drifting in between.

What is a good FTP in watts per kilogram?

As a rough guide used by coaches, about 2 W/kg is a recreational rider, about 3 W/kg is a fit club rider, about 4 W/kg is strong, and about 5 W/kg or more for an hour is professional level. At the defaults, 250 W at 75 kg is 3.33 W/kg, a fit club rider. At the test case, 300 W at 75 kg is 4.00 W/kg, strong. Always pair a W/kg figure with a duration before comparing it with anyone else: a 6 W/kg sprint for ten seconds and a 6 W/kg hour are different universes, and Zone 7 exists precisely because short efforts sit far above anything sustainable. The honest comparison is with your own last test, six to eight weeks ago.

Calculator Sources

TrainingPeaks: Power Training Levels — Dr Andrew Coggan’s seven power levels, the percentage bands, the descriptions of each zone and the 20 minute field test for threshold power.

Cycling power meter — power at the pedals as the measured quantity, functional threshold power, and watts per kilogram as the standard comparison.

Bicycle performance — the power balance behind cycling power, drag, rolling resistance and gradient, for the context behind the watts.

UCI — the world governing body for cycling, for the sport and equipment context behind the calculator.

Disclaimer

This calculator builds the seven Coggan and Allen power zones from your functional threshold power using the multipliers 0.55, 0.75, 0.90, 1.05, 1.20 and 1.50, with Zone 6 capped at 150% and Zone 7 above 150% under the widely published capped rendering; Coggan’s original TrainingPeaks table leaves Level 6 open ended above 121% and gives Level 7 no percentage. FTP is an estimate from a field test, usually 95% of a 20 minute all-out average power, not a lab measurement, and your true threshold can differ from the test figure. The Ironman and 70.3 pacing ranges of 65 to 75% and 75 to 85% of FTP are published coaching guidance, not guarantees, and an FTP tested fresh falls as a long bike leg goes on. The results are estimates for general training planning, not medical advice. If you have a heart condition, take heart-rate-lowering medicine, or are new to exercise, talk to your doctor before training by power or heart rate.

ADVERTISEMENT

ADVERTISEMENT

Last updated: 27 November 2026