A hole can be within tolerance on X and within tolerance on Y and still be out of position, because GD&T position tolerance is a round zone, not a square one. This free true position calculator does the check the drawing actually calls for.
Enter the X and Y deviations of the measured feature from its true (basic) position, in inches, as measured minus basic. Either value may be negative; the formula squares both, so direction does not affect the result. Enter the position tolerance from the feature control frame as a diameter. Leave the tolerance at 0 to skip the pass/fail check.
Please enter numbers for the X and Y deviations.
| X Deviation (in) | Y Deviation (in) | True Position (in) | Result vs Tolerance |
|---|
Each row is a different pair of X and Y deviations, checked against the position tolerance entered above. True position grows with the square root of the sum of the squared deviations, so an error split across both axes is worse than the same error on one axis alone.
Founder & CEO, Techraxy
Faiq Ur Rahman is a web designer, digital product developer, and Founder of Techraxy, a growing platform of online calculators and utility tools. He specializes in building structured, user-friendly tools focused on finance, health, conversions, productivity, and everyday problem-solving. He is passionate about developing practical digital solutions that make complex tasks simpler for users worldwide.
User Ratings:
ADVERTISEMENT
ADVERTISEMENT
A hole can be within tolerance on X and within tolerance on Y and still be out of position, because GD&T position tolerance is a round zone, not a square one. This free true position calculator does the check the drawing actually calls for. Enter the X and Y deviations of the measured feature from its true position, plus the position tolerance from the feature control frame, and it gives the true position error as a diametral value, in inches and millimetres, with a pass or fail verdict against the tolerance.
True position is the theoretically exact location of a feature, a hole centre, a pin axis or a boss, defined by basic dimensions (the boxed numbers on the drawing) measured from a datum reference frame. The position symbol in the feature control frame states how far the real feature is allowed to wander from that perfect spot, and the tolerance zone is a circle, or a cylinder in three dimensions, centred on the true position. That round zone is the whole point of true position: it matches how a fastener or pin actually fits, and it gives about 57 percent more usable area than the square zone of a plus/minus coordinate tolerance with the same worst-case limit.
The true position error is a diametral value: TP = 2 x square root(dx squared + dy squared). The square root term is the radial deviation, the straight-line distance from the true position to the measured point. Doubling it converts that radius into the diameter of the smallest tolerance zone centred on true position that contains the measured point, which is the form the tolerance in the feature control frame is written in. Forgetting the factor of 2 is the single most common true position mistake: it halves every result and makes bad parts look good.
Radial deviation (in) = square root(dx squared + dy squared)
True position, diametral (in) = 2 x radial deviation
True position (mm) = true position (in) x 25.4
Margin to tolerance (in) = position tolerance – true position
Result = PASS when true position is less than or equal to the position tolerance, otherwise FAIL
In the formulas, dx is the measured X minus the basic X and dy is the measured Y minus the basic Y. The same idea extends to three dimensions by adding dz squared under the square root. For a legacy drawing with plus/minus coordinate tolerances, the equivalent diametral position tolerance for a hole located plus/minus 0.1 mm in both axes is 2 x square root(0.1 squared + 0.1 squared) = 0.2828 mm.
This calculator checks the basic position error only. It does not add bonus tolerance for MMC (maximum material condition) or LMC modifiers, which need the feature’s actual mating size as well as its location.
A hole measured 0.003 inches off in X and 0.004 inches off in Y from its true position, against a position tolerance of 0.010 inches diameter. The deviations form a scaled 3-4-5 triangle, so the arithmetic comes out exact. All steps below use the unrounded values; displayed figures are rounded to four decimals.
dx squared = 0.003 squared = 0.000009.
dy squared = 0.004 squared = 0.000016.
Sum of squares = 0.000009 + 0.000016 = 0.000025.
Radial deviation = square root(0.000025) = 0.0050 in.
True position = 2 x 0.0050 = 0.0100 in.
True position in millimetres = 0.0100 x 25.4 = 0.2540 mm.
Margin = 0.0100 – 0.0100 = 0.0000 in, so the feature passes exactly at the tolerance limit.
So the hole is 0.0050 inches from its true position radially, which is a true position error of 0.0100 inches diametral, and it passes a 0.010 inch tolerance with no margin to spare. A hole at the same radial distance but with the error all on one axis would give the same true position: the formula only cares about the combined distance.
Because the tolerance zone is a diameter, not a radius. The square root of dx squared plus dy squared gives the radial distance from the true position to the measured point, which is a radius. The position tolerance in the feature control frame is written as a diameter, with the diameter symbol in front of it. Doubling the radial deviation converts it to the diametral value the tolerance uses, so the two can be compared directly. Skipping the doubling makes every result half of what it should be.
A plus/minus tolerance gives a square zone: the feature can be up to the limit in X and up to the limit in Y independently, which accepts a point on the diagonal that is 41 percent further out than the limit on either axis. True position gives a round zone of a stated diameter, which treats every direction equally and matches how a mating pin or fastener actually fits. A round zone whose diameter equals the square’s diagonal has about 57 percent more area than the square, so converting a position tolerance into plus/minus coordinates rejects good parts.
Basic dimensions are the theoretically exact dimensions that locate the true position, shown in a rectangular box on the drawing. They carry no tolerance of their own: all of the allowed variation comes from the geometric tolerance in the feature control frame. The deviations entered here are the measured coordinates minus those basic coordinates.
That is exactly the case true position is designed to catch. A hole 0.008 inches off in X and 0.008 inches off in Y is within a plus/minus 0.010 tolerance on each axis, but its radial deviation is 0.0113 inches and its true position is 0.0226 inches, which fails a 0.010 inch position tolerance. The combined error is what matters, not each axis on its own.
No. When a position callout carries an MMC modifier, the allowable tolerance grows as the feature departs from its maximum material condition, and working that out needs the feature’s actual mating size as well as its location. This calculator checks the stated tolerance only, which is the conservative check: a part that passes here passes with bonus tolerance too, but a part that fails here might still pass once bonus tolerance is counted. For MMC work, use the feature’s actual size with the virtual condition formula from ASME Y14.5.
This calculator computes the diametral true position error from the X and Y deviations you enter, using the standard GD&T formula. It checks the stated position tolerance only and does not account for bonus tolerance at MMC or LMC, datum shift, or measurement uncertainty, all of which can change an inspection decision. For formal inspection reports and acceptance decisions, follow the drawing, the applicable standard (ASME Y14.5 or ISO 1101) and your quality procedures, and have borderline results reviewed by a qualified inspector.
ADVERTISEMENT
ADVERTISEMENT