How much will a beam sag under load, and is that sag acceptable? This free beam deflection calculator answers both questions for a simply supported beam.
Span is the clear distance between the two supports. The Douglas Fir-Larch value of 1,600 ksi is the NDS design value of E for Select Structural grade; textbook values for Douglas fir run near 1,900 ksi. For an I-beam, channel or other rolled shape, choose "Enter moment of inertia I directly" and take I from the steel section tables. Depth is measured in the direction of the load: doubling the depth multiplies I by eight.
The point load acts at midspan, where it causes the largest deflection. The UDL is spread evenly over the whole span. The beam's own weight is NOT included: add it to the load if it matters for your beam.
Please enter values above 0 for the span, E, the section and the load.
| Span | Deflection | L/360 Limit | Within L/360 |
|---|
Each row uses the load case, material and section entered above, at a different span. Deflection grows with the cube of the span for a point load and with the fourth power for a UDL, so doubling the span multiplies the deflection by 8 or 16.
Founder & CEO, Techraxy
Faiq Ur Rahman is a web designer, digital product developer, and Founder of Techraxy, a growing platform of online calculators and utility tools. He specializes in building structured, user-friendly tools focused on finance, health, conversions, productivity, and everyday problem-solving. He is passionate about developing practical digital solutions that make complex tasks simpler for users worldwide.
User Ratings:
ADVERTISEMENT
ADVERTISEMENT
How much will a beam sag under load, and is that sag acceptable? This free beam deflection calculator answers both questions for a simply supported beam. Enter the span, pick a material or enter the modulus of elasticity directly, give the section size or the moment of inertia, and choose a center point load or a uniformly distributed load. It shows the maximum deflection at midspan in inches and millimeters, the span to deflection ratio, the maximum bending moment and the support reactions, and it checks the deflection against the L/360 and L/240 limits from IBC Table 1604.3. The Compare Spans tab shows how the deflection changes as the span grows, which is the fastest way to see why span dominates every beam decision.
Beam deflection is the amount a beam bends downward under load, measured at the point where the sag is greatest. For a simply supported beam that point is midspan, for both a center point load and a uniformly distributed load. Deflection is a serviceability question, not a strength question: a beam can be far from breaking and still sag enough to crack plaster, bounce underfoot or look wrong. That is why building codes limit deflection as a fraction of the span, most commonly L/360 for floor live load and L/240 for floor total load, rather than as an absolute number of inches.
Two things set the size of the answer. The first is the load and the span: deflection grows with the cube of the span for a point load and with the fourth power for a distributed load, so doubling the span multiplies the deflection by 8 or 16. The second is the bending stiffness, E times I: E is the material’s modulus of elasticity, how hard the material is to stretch, and I is the second moment of area, how well the cross-section’s shape resists bending. Doubling I halves the deflection exactly. For a rectangular section I = b x h cubed / 12, so depth matters far more than width: doubling the depth multiplies I by eight.
For wood beams under long-term load there is one more effect to know about. Wood creeps under sustained load, and NDS 3.5.2 multiplies the dead and long-term load deflection by 1.5 for dry-service lumber and LVL, so the short-term elastic deflection this calculator gives understates the long-term sag of a wood beam carrying a permanent load.
If the roof is framed with trusses rather than solid beams, the Roof Truss Calculator works out the truss layout instead, since a truss carries load as axial forces in its members rather than by bending like a beam.
Deflection is only one of the checks a beam needs: the Beam Load Calculator works out the largest load the same beam can carry from its section modulus and allowable stress.
Moment of inertia, rectangle (in^4) = b x h cubed / 12
Center point load, maximum deflection (in) = P x L cubed / (48 x E x I)
Center point load, maximum bending moment (lb-in) = P x L / 4
Center point load, support reaction each end (lb) = P / 2
UDL, maximum deflection (in) = 5 x w x L to the fourth / (384 x E x I)
UDL, maximum bending moment (lb-in) = w x L squared / 8
UDL, support reaction each end (lb) = w x L / 2
L/360 deflection limit (in) = span (in) / 360
L/240 deflection limit (in) = span (in) / 240
Deflection (mm) = deflection (in) x 25.4
In these formulas P is the point load in pounds, w is the distributed load in pounds per inch, L is the span in inches, E is the modulus of elasticity in psi and I is the moment of inertia in in^4. The calculator converts the inputs to those units: span in feet times 12, E in ksi times 1,000, and UDL in lb/ft divided by 12. The UDL conversion is the classic trap in this calculation: entering w in lb/ft directly into a formula that expects lb/in makes the deflection wrong by a factor of 12 to the fourth, or 20,736.
The L/360 and L/240 limits come from IBC Table 1604.3: floor members are held to L/360 under live load and L/240 under dead plus live load. Roof members get L/360 under a plaster ceiling, L/240 under a non-plaster ceiling and L/180 with no ceiling at all. Both formulas are the Euler-Bernoulli elastic solutions for a simply supported beam, pinned at one end and on a roller at the other, with small deflections and the load acting in a plane of symmetry.
A Douglas Fir-Larch beam, 12 ft span, 6 in wide and 12 in deep, carrying a 2,000 lb point load at midspan, with E = 1,600 ksi. All steps below use the unrounded values; displayed figures are rounded only at the end.
Span in inches = 12 x 12 = 144 in.
E in psi = 1,600 x 1,000 = 1,600,000 psi.
Moment of inertia = 6 x 12 cubed / 12 = 6 x 1,728 / 12 = 864 in^4.
Deflection = 2,000 x 144 cubed / (48 x 1,600,000 x 864) = 5,971,968,000 / 66,355,200,000 = 0.09 in exactly, displayed as 0.090 in.
Deflection in millimeters = 0.09 x 25.4 = 2.286 mm, displayed as 2.29 mm.
Span to deflection ratio = 144 / 0.09 = 1,600, displayed as L/1,600.
L/360 limit = 144 / 360 = 0.40 in, displayed as 0.400 in; the deflection uses 0.09 / 0.40 x 100 = 22.50 percent of the limit, so it passes.
L/240 limit = 144 / 240 = 0.60 in, displayed as 0.600 in; the deflection uses 15.00 percent of the limit, so it passes.
Maximum bending moment = 2,000 x 144 / 4 = 72,000 lb-in = 6,000 lb-ft.
Support reaction each end = 2,000 / 2 = 1,000 lb.
So the beam sags 0.090 in at midspan, well inside the L/360 limit of 0.400 in.
Because the span enters the deflection formula as a power, not a multiple. For a center point load the deflection is proportional to L cubed, so doubling the span multiplies the deflection by 2 cubed, or 8. For a uniformly distributed load it is proportional to L to the fourth, so doubling the span multiplies the deflection by 2 to the fourth, or 16. That is why serviceability, not strength, often governs long spans: a beam that is plenty strong enough can still sag too much, and the fix is usually a deeper section or a shorter span rather than a stronger material.
They are deflection limits expressed as a fraction of the span. L/360 means the beam may sag no more than its span divided by 360, so a 12 ft (144 in) beam may move 0.40 in. The values come from IBC Table 1604.3: floor members are held to L/360 under live load and L/240 under dead plus live load. Roof members get L/360 under a plaster ceiling, L/240 under a non-plaster ceiling and L/180 with no ceiling. Deflections beyond about L/300 of the span may also be visually objectionable and can cause architectural damage even when nothing is structurally wrong.
Yes, if it matters for your beam, and this calculator does not add it for you. The beam’s self-weight acts as a uniformly distributed load, so work out the weight per foot from the section size and the material density and add it to the UDL. For a steel beam the self-weight is often a small part of the total load, but for a long concrete beam it can be the largest load on the member. The L/240 check is the total-load check, so it is the one that should include self-weight and dead load.
Both numbers are right in different contexts. The textbook value of about 1,900 ksi (13.1 GPa) is the average modulus of clear Douglas fir wood measured in a laboratory. The 1,600 ksi used here is the NDS design value of E for Douglas Fir-Larch, Select Structural grade, beams and stringers: the value the timber design code tells engineers to use for real graded lumber, which contains knots, slope of grain and other natural variation. The calculator uses the design value because its readers are sizing real lumber, and the widget note states both values so nobody is surprised.
Not directly. Fixing both ends changes the formulas: a fixed-end beam under a UDL deflects w x L to the fourth / (384 x E x I) at midspan, exactly one fifth of the simply supported value, and under a center point load it deflects P x L cubed / (192 x E x I), one quarter of the simply supported value. In practice most real connections are neither perfectly pinned nor perfectly fixed, so the simply supported result is the conservative choice for deflection: a beam that passes as simply supported will deflect less if its ends turn out to be partly restrained.
This calculator gives estimates for a simply supported beam using the Euler-Bernoulli elastic formulas, based on the values you enter. It assumes the beam stays elastic, deflects only a small amount compared with its span, is prismatic, and is loaded in a plane of symmetry, with pinned and roller supports that are free to rotate. It does not include the beam’s self-weight, long-term creep in wood, shear deflection, lateral-torsional buckling, bearing at the supports or any load other than the one load case selected. Deflection limits vary by code, jurisdiction and what the beam supports. The results are for planning and estimating only and are not a substitute for a design by a licensed engineer.