Every rafter has one critical cut: the birdsmouth. It’s the notch where the rafter meets the wall plate. Cut too deep and you’ve removed so much material that the rafter loses strength. Cut too shallow and the rafter rocks on the plate instead of bearing flat. This calculator takes your building span, pitch, and plate width and returns the exact seat cut and plumb cut dimensions. It also checks whether the perpendicular notch depth stays within the 25% IRC limit, since that’s the number that fails inspections. Rafter length, HAP, ridge height, and total rafter count come out of the same inputs. Framers use it on layout day. Owner-builders use it to sanity-check a set of plans before cutting a single board. Imperial and metric both work.
How to Use the Birdsmouth Cut Calculator
Pick your unit system. Imperial uses inches and feet. Metric uses millimeters and meters.
Enter the building span and length. Span is wall-to-wall across the ridge. Length is along the ridge.
Choose your pitch format. Rise:12 is the standard way to express roof slope in the US. Percent and degrees work too.
Enter the rafter spacing, typically 16 or 24 inches on center.
Pick a rafter size or enter a custom width and depth. Depths run from 4 inches (2×4) up to 12 inches (2×12).
Set the wall plate width and the horizontal roof overhang.
Choose seat cut mode. Most codes want the seat cut equal to the plate width. You can override it.
Pick a notch depth limit. IRC uses 25%. Some codes go to 33%. A conservative 20% is also available.
Add collar ties and connectors if your design needs them, then enter unit costs and read the result.
How the Birdsmouth Cut Calculator Formula Works
The birdsmouth math runs from run and pitch. Run is half the span after subtracting the ridge board. Rise is run times pitch. The rafter line length and every birdsmouth dimension follow from those two numbers.
Formula: Run = (Span − Ridge Thickness) ÷ 2
Formula: Rise = Run × Pitch Ratio
Formula: Rafter Line Length = Run ÷ cos(atan(Pitch Ratio))
Formula: Total Rafter Length = (Run + Overhang) ÷ cos(atan(Pitch Ratio))
Formula: Plumb Cut Height = Seat Cut × tan(atan(Pitch Ratio))
Formula: Perpendicular Notch Depth = Seat Cut × sin(atan(Pitch Ratio))
Formula: Height Above Plate (HAP) = Rafter Depth ÷ cos(atan(Pitch Ratio))
The perpendicular notch depth is the number that matters most for code. It’s the vertical thickness of material removed from the rafter’s bottom edge. IRC caps that at 25% of the rafter depth. A 2×10 with a 9.25-inch depth gives a max notch of 2.31 inches. If your seat cut produces a deeper notch than that, you either reduce the seat cut or step up to a bigger rafter.
Plumb cut height is the vertical length of the cut on the wall side of the birdsmouth. It’s what sets how high the rafter sits above the plate. HAP is measured from the top of the plate to the top edge of the rafter. Together, plumb cut height and HAP position the rafter for the rest of the roof.
Rafter count comes from building length and spacing. A 40-foot building at 16 inches on center needs 31 rafters per side, so 62 total. The tool rounds up and reports the actual spacing, which is usually a fraction less than the target.
Worked Example
A garage with a 26-foot span, 36-foot length, and an 8:12 pitch. 2×10 rafters at 16 inches on center. Wall plate is 3.5 inches wide. 18-inch overhang. Standard seat cut equal to plate width.
Step 1 — Run. (26 − 0.125) ÷ 2 = 12.94 ft.
Step 2 — Pitch angle. 8:12 = 0.6667 ratio. atan(0.6667) = 33.69°.
Step 3 — Rise. 12.94 × 0.6667 = 8.63 ft.
Step 4 — Rafter line length. 12.94 ÷ cos(33.69°) = 12.94 ÷ 0.832 = 15.55 ft.
Step 5 — Total rafter length. (12.94 + 1.5) ÷ 0.832 = 17.35 ft.
Step 6 — Plumb cut height. 3.5 in × tan(33.69°) = 3.5 × 0.6667 = 2.33 in.
Step 7 — Perpendicular notch depth. 3.5 × sin(33.69°) = 3.5 × 0.5547 = 1.94 in.
Step 8 — Notch check. 1.94 ÷ 9.25 = 21% of rafter depth. IRC limit is 25%, so the cut passes.
Step 9 — HAP. 9.25 ÷ cos(33.69°) = 9.25 ÷ 0.832 = 11.12 in.
Step 10 — Rafter count. 36 ft at 16 in on center: 28 spaces, 29 rafters per side, 58 total. Actual spacing 15.72 in.
Step 11 — Ridge board. 36 + 2 × 1.5 = 39 ft.
Interpretation: The birdsmouth passes IRC without adjustment. You need 58 rafters at 17.35 feet each, 610 feet of total rafter lumber, and a 39-foot ridge board. Notch depth stays 1.94 inches, well within the 2.31-inch limit.